Model 909B Dosimeter Charger
The Model 909B Charger LED Reading Light reduces re-zeroing time and effort by eliminating the need to remove the dosimeter from the Charger for reading. Simply view the scale while the dosimeter is resting lightly on the charger contact after re-zeroing. Reading in the same orientation as charging also minimizes the effect that gravitational induced fiber movement has on dosimeter accuracy and precision. The Model 909B Charger charging contact is spring-loaded and has a positive mechanical stop. This design feature makes it virtually impossible to damage dosimeters through excessive charging force.
- Capable of charging any Direct-Reading Dosimeter
- Conforms to ANSI N42.6-1980
- Operates on two 1.5 V “AA” Batteries
- Has the ability to “Kick” or remove all residual charge from dosimeters properly, which prevents spurious upscale fiber movement
- LED Reading Light to allow for easy charging/viewing
- Residual static charge removed for improved accuracy
Charging Voltage: 40V to 220V
Radiation Alert Personal Pen Direct-Reading Dosimeter - W725, 0-5R with Sapphire Window
Model W725

Personal Pen Dosimeters Model W725
Direct-Reading Dosimeter - W725, 0-5R with Sapphire Window Model W725 0-5R
Direct-Reading Dosimeter with Sapphire Window
Model W725 Order (4349)
The Direct-Reading Dosimeter is pocket-size, carbon-fiber electroscope with an ion chamber for detecting and indication of integrated exposure to Gamma and X-Ray radiation. It has a thin wall which permits the penetration and detection of radiation. This model comes with a hardened sapphire window that won't scratch even in the toughest of conditions.
Dosimeters are extremely sensitive instruments. Although they are constructed for rugged use, they should receive the same care as a wristwatch. Since dosimeters are hermetically sealed at the factory, they cannot be repaired or adjusted in the field. Therefore, if instrument malfunctioning is experienced, the instrument should be returned to the factory or your dealer. Dosimeters may be maintained in operating condition simply by cleaning the eyepiece lens and the charging switch insulator with clean water and a cloth that is free of lint and grit. Make sure the charging switch insulator is absolutely free of lint and moisture at all times. Caution: Do not insert any sharp objects into, or tamper with parts in the charging switch recess. Irreparable damage may be done.
Arrow-Tech, Inc. recommends a yearly calibration of the Direct-Reading Dosimeter which is generally consistent with good health physics practices. More frequent calibration may be necessary should the user's license require a shorter calibration interval.
Licensed from the U.S. Government under Patent No. 5,426,305
Specifications:
Radiation Detected: Gamma and X-Ray from 16 keV to 6 MeV
Range: 0-5R
Detector: Fiber-Electrometer mounted in an Electrically Conductive Plastic Ion Chamber
Detector Housing: Very low permeability plastics - Hermetically-Sealed
Accuracy: +/– 10% of true exposure
Rate Response: Dose rate independent for Gamma and X-Ray
Electrical Leakage: Less than 1.0% of full scale for 24 hours at 50 C
Temperature Range: -20 degrees C to +50 degrees C
Relative Humidity: Up to 90%
Dimensions: 4.5” (12.4 cm) Length X .6“ (1.5 cm) Diameter
Weight: 1.0 oz. (25 grams)
Finish: Natural Matte Gray with a Metal Clip
Warranty: Two Year Limited Warranty
Shelf Life: 20 Years
Specifications: ANSI N13.5 and ANSI N322-1997
DMC 3000 Electronic Personal Dosimeter

The DMC 3000 - Personal Electronic Dosimeter - X-ray & Gamma
The DMC 3000 covers a wide range of X-Ray and Gamma radiation detection field from 15keV to 7Mev and linear response to dose rate fields from natural background up to more than 10 Sv/h. The pass-by data exchange feature gives unequal operational flexibility. In-motion reading allows dose management by sub-zone as well as real-time location tracking of personnel.
FEATURES
- Loud alarm, 85 dB (A) typical, (> 90 dB (C) peak)
- Vibrating alarm
- Highly visible backlit display
- Optional beta, neutron or telemetry module
- Factory upgradeable firmware
- Simple 2-button navigation
- Extended dose rate alarms
- Dual ultrabright LED alarm
- Superior X-ray and gamma energy response
- Meets or exceeds applicable IEC and ANSI standards
- Designed for ruggedness and durability
TECHNICAL SPECIFICATIONS:
Radiological Characteristics
- Compliant with IEC 61526Ed. 3, ANSI 42.20(*) (*) isotropy 241Am and 137Cs with ± 75° angle Measurement and display
- Energy response better than ± 20% (typically ± 10%)
- Accuracy Hp(10): ≤ ± 10%* (137Cs, ~ 24 mSv/h); ≤ ± 15%*, (241Am, ~ 23 mSv/h); ≤ ± 19%** X-ray 16keV (*including ± 5% extended uncertainty k=2); (** including ± 9% extended uncertainty k=2)
- Display dose: 1 µSv to 10 Sv (0.1 mrem to 1000 rem)
- Display rate: 10 µSv/h to 10 Sv/h (1 mrem/h to 1000 rem/h) or 1 µSv/h to 10 Sv/h (0.1 mrem/h to 1000 rem/h) extended option.
- Dose Rate Linearity: < ± 20% up to 10 Sv/h (1000 rem/h) (Co and X H30 20 keV); < ± 20% up to 6 Sv/h (600 rem/h) (Pulsed X-rays 20 ms width, 1, 10 & 20 pps)
Electrical Characteristics
- Standard AAA (LR03) 1.5 V Alkaline battery
9 calendar month battery life (typical, 8 h per day,
5 days per week in run mode, without excessive alarms)*
- 2500 h battery life in continuous run, without excessive alarm
Mechanical Characteristics
- Rugged, high impact polycarbonate-ABS case
- Dimensions: 86 x 56 x 21 mm (3.4 x 2.2 x 0.8 in) without clip
- Weight with alkaline battery and clip: < 88 g (3.1 oz)
- Worn by a replaceable clips (2 different style back clips or one a front-facing clip for DMC worn inside the pocket)
Environmental Characteristics
- Temperature range: -10°C to 50°C (14°F to 122°F): deviation in response less than ± 5%
- Relative humidity: < 90% at 42°C (108°F)
- Storage: -20°C to 71°C (-4°F to 160°F)
- Shock, vibration and drop resistant (1.5 meter on concrete)
- Waterproof IP67: 1m (39 in) during 1 hour
- EMC: complies and exceeds standards by a large margin ( compliant, certificate number: 153720)
- MIL STD 461F RS103 (pulsed electric field): exceeds 200 V/m from 30 kHz to 5 GHz
- MIL STD 461F RS101 (magnetic field 30 Hz - 100 kHz)
- Factory calibration approved under ISO/IEC 17025, COFRAC accreditation Nber 2-1663
Radiation Alert Personal Pen Dosimeters Model W138

Personal Pen Dosimeters Model W138
- Rugged charger requires no batteries — simply squeeze the trigger of this piezoelectric generator to move the hairline fiber inside the dosimeter back to zero
- Clamping mechanism automatically locks the dosimeter in place
- Charger is easy to operate and requires only few squeezes of the trigger for each dosimeter
Direct-Reading Dosimeter with Sapphire Window
Model W138 (Order 4329)
The Direct-Reading Dosimeter is a pocket-size, carbon-fiber electroscope with an ion chamber for detecting and indication of integrated exposure to Gamma and X-Ray radiation. It has a thin wall which permits the penetration and detection of radiation. This model comes with a hardened sapphire window that won't scratch even in the toughest of conditions.
Dosimeters are extremely sensitive instruments. Although they are constructed for rugged use, they should receive the same care as a wristwatch. Since dosimeters are hermetically sealed at the factory, they cannot be repaired or adjusted in the field. Therefore, if instrument malfunctioning is experienced, the instrument should be returned to the factory or your dealer. Dosimeters may be maintained in operating condition simply by cleaning the eyepiece lens and the charging switch insulator with clean water and a cloth that is free of lint and grit. Make sure the charging switch insulator is absolutely free of lint and moisture at all times. Caution: Do not insert any sharp objects into, or tamper with parts in the charging switch recess. Irreparable damage may be done.
Arrow-Tech, Inc. recommends a yearly calibration of the Direct-Reading Dosimeter which is generally consistent with good health physics practices. More frequent calibration may be necessary should the user's license require a shorter calibration interval.
Licensed from the U.S. Government under Patent No. 5,426,305
Specifications:
Radiation Detected: Gamma and X-Ray from 16 keV to 6 MeV
Range: 0-200mR
Detector: Fiber-Electrometer mounted in an Electrically Conductive Plastic Ion Chamber
Detector Housing: Very low permeability plastics - Hermetically-Sealed
Accuracy: +/– 10% of true exposure
Rate Response: Dose rate independent for Gamma and X-Ray
Electrical Leakage: Less than 1.0% of full scale for 24 hours at 50 C
Temperature Range: -20 degrees C to +50 degrees C
Relative Humidity: Up to 90%
Dimensions: 4.5” (12.4 cm) Length X .6“ (1.5 cm) Diameter
Weight: 1.0 oz. (25 grams)
Finish: Natural Matte Gray with a Metal Clip
Warranty: Two Year Limited Warranty
Shelf Life: 20 Years
Specifications: ANSI N13.5 and ANSI N322-1997





ON SALE NOW!! Do you know if you are being exposed to harmful radiation? Dose - i - Electronic Personal Dosimeter affordable hand-held portable radiation meter is small enough to go anywhere and as sensitive as the $1000 professional models since Dose - i - Electronic Personal Dosimeter Detects minuscule amounts of gamma, beta or X-rays. The unit Silicon semiconductor detects all gamma and beta isotopes released by nuclear power plants such as iodine and cesium. It is ideal for Homeland Security and for detecting environmental / industrial contamination. It can be used to screen for radiation in air, food and water. Designed for nontechnical persons the Dose - i - Electronic Personal Dosimeter has a battery life of 720 hours, Silicon semiconductor detector; and yet offers easy one-button operation. (see specifications)
Radiation Measured | Gamma (X) rays |
---|---|
Detector | Silicon semiconductor |
Measurement Range | 0.001mSv to 999.9mSv (0.1mrem to 99.99mrem) 0.001mSv/h to 999.9mSv/h (0.1mrem/h to 99.99mrem/h) for dose measurement |
Display Range | Accumulated Dose: 0.001mSv to 999.9mSv (0.1mrem to 99.99mrem) Dose Rate*: 0.001mSv/h to 999.9mSv/h (0.1mrem/h to 99.99mrem/h) |
Accuracy | ≤ ±10% (0.01mSv to 999.9mSv (1mrem to 99.99rem), 137Cs) |
Energy Range | 35keV to 3MeV |
Energy Response | ≤ ±20% (60keV to 1.5MeV, 137Cs reference) |
Angular Response | ≤ ±20% (Up to ± 60 degree vertical and horizontal, 137Cs) |
Dose Rate Linearity | ≤ ±10% (137Cs) |
Display | 4-digit OLED (0.001 to 999.9) |
Indication Data | Dose, Dose rate, Operating time, Alarm |
Alarm Volume | 60dB (at 20cm) |
Data Storage | Trend data (Up to 600 data) |
Power Supply | Primary Battery (CR2450) x 1 |
Battery Lifetime | 720 hours or more (without alarm / communication) |
Communication | Infrared communication (Option: communication cable and software) |
Operating Temperature | -10℃ to 40℃ (14°F to 104°F) |
Operating Humidity | Up to 90%RH |
Dimensions | 30(W) x 110(H) x 12(D) mm approx. (1.2(W) x 4.3(H) x 0.5(D) in approx.) |
Weight | 60g approx. (0.13lb approx.) |
*Note) Dose-i indicates rough value for dose rate measurement in low radiation field such as less than 1mSv/h (100mrem/h), so it should be used just for reference.
- 1